How big a fireplace hearth must be, and how close a mantel can sit.
Two measurements decide whether a fireplace passes inspection: how far the hearth reaches into the room, and how close wood can get to the opening. Who sets them depends on the kind of fireplace you have. Here are the numbers, and where each one comes from.
We get the hearth and mantel questions in both showrooms, usually from someone halfway through a remodel. How far out does the stone have to come? Can the new wood mantel go right above the opening? The answers are short. The catch is that there are two sets of rules, and you need to know which one your fireplace follows.
First, which kind of fireplace is it?
A masonry fireplace is built on site from brick, block or stone, with a firebrick firebox. The residential code sets its hearth and its clearances.
A factory-built fireplace is a metal firebox made in a plant and framed into the wall. Most new homes have one. For these, the code hands the rules to the manufacturer. Section R1004.1 says a factory-built wood fireplace must be tested to UL 127 and installed to its listing. R1004.2 says its hearth extension follows that listing too. A gas fireplace works the same way: section G2434.1 says it is listed to ANSI Z21.50 and installed to the manufacturer's instructions.
So for a factory-built or gas unit, the manual is the rule book. Read the next section if you have masonry. Skip to the manual example if you do not.
Georgia adopts the International Residential Code with state amendments. The sections quoted here are from the 2024 IRC as UpCodes publishes it for Georgia. Ask your city or county building department which edition it enforces before you build.
The hearth on a masonry fireplace
The code splits the hearth into two parts. The hearth is the floor of the firebox, where the fire sits. The hearth extension is the part that reaches out into the room to catch sparks and rolling logs.
- What it is made of. Concrete or masonry, supported by noncombustible materials, and reinforced to carry its own weight and anything put on it.
- Nothing burnable underneath. Combustible material cannot stay against the underside of either part after construction. Wood forms used to pour a hearth have to come out.
- The hearth. At least 4 inches thick.
- The hearth extension. At least 2 inches thick.
- A raised firebox. If the bottom of the firebox opening sits at least 8 inches above the hearth extension, the extension can be as thin as 3/8 inch of brick, concrete, stone, tile or other approved noncombustible material.
How far the hearth extension has to reach
Section R1001.10 sets the size from the fireplace opening. Measure the opening's width and height and multiply them to get its area.
- Opening under 6 square feet. The extension reaches at least 16 inches in front of the opening and at least 8 inches past each side.
- Opening of 6 square feet or more. At least 20 inches in front and 12 inches past each side.
Two examples. A 30 by 24 inch opening is 5 square feet. Its extension needs 16 inches of depth and 8 inches past each side, so it is at least 46 inches wide. A 36 by 30 inch opening is 7.5 square feet. That one needs 20 inches of depth and 12 inches past each side, so at least 60 inches wide.
An opening of exactly 6 square feet, such as 36 by 24 inches, takes the larger size. Measure before you order stone. A hearth that comes up 2 inches short is a hard thing to fix after the grout is set.
How close a wood mantel can sit on masonry
Section R1001.11 lets a combustible mantel or trim sit directly on the masonry face around the opening, with two limits:
- The 6 inch rule. No combustible material within 6 inches of the fireplace opening.
- The projection rule. Within 12 inches of the opening, combustible material cannot stick out more than 1/8 inch for every 1 inch it sits from the opening.
Worked through, that looks like this. At 6 inches from the opening, wood trim can stick out 3/4 inch. At 8 inches, 1 inch. At 12 inches, 1 1/2 inches. Past 12 inches, this rule sets no projection limit.
That is why most mantel shelves on masonry fireplaces sit 12 inches or more above the opening. A shelf 8 inches deep cannot go lower than that, because no point inside 12 inches allows 8 inches of projection.
The same section covers the edges of wood siding, flooring and drywall that butt into the fireplace sides and the hearth extension. Those edges have to stay at least 8 inches from the inside of the firebox lining, or 12 inches when the opening is 6 square feet or more. Framing lumber stays 2 inches from the front and sides of the masonry and 4 inches from the back.
A factory-built example: the Tahoe Luxury 42
Here is what a manual's version looks like. We used one current manual from Empire Comfort Systems, the maker of White Mountain Hearth: the Tahoe Luxury Traditional direct-vent gas fireplace, model DVCX42FP, manual 41410-1-1024. It is certified to ANSI Z21.50.
The hearth first. This manual lists 0 inches of clearance to the floor. It says the unit can sit on a flat, hard combustible surface, a raised wooden platform or four corner supports. It does not call for a masonry hearth extension the way R1001.10 does. That is the listing at work. Do not assume another model reads the same.
Now the mantel. The manual's chart pairs how far a mantel sticks out with how high it has to sit above the top edge of the fireplace opening:
- Flush trim, 0 inches deep: at least 17 inches above.
- 2 inches deep: 18 3/4 inches.
- 4 inches deep: 20 3/8 inches.
- 6 inches deep: 22 1/8 inches.
- 8 inches deep: 23 3/4 inches.
- 10 inches deep: 25 1/2 inches.
- 12 inches deep: 25 1/2 inches.
Compare that with the masonry rule. A masonry fireplace could take an 8 inch shelf 12 inches above the opening. This gas fireplace needs that same shelf at 23 3/4 inches.
The manual adds a few other limits worth knowing before you plan the wall:
- The framing header sits at least 6 inches above the top of the fireplace.
- Only noncombustible material can cover the black fireplace front.
- The side of the fireplace stays 6 inches from an adjacent side wall, and the ceiling stays 84 inches above the bottom of the fireplace.
- It has not been tested or approved with a television or other electrical appliance installed above it.
- Nothing gets attached to the mantel. Empire calls stockings and garland a fire hazard.
This manual lists no shield or kit that lets a mantel sit lower than the chart. If the manual for a different model offers one, it will name the part and give the new numbers. If it does not, the chart is the limit.
What this means for a live-edge wood mantel
The live-edge mantels on our showroom wall are wood. Wood is combustible, however thick or dense the slab is. On a masonry fireplace, the mantel follows the 6 inch rule and the projection rule. On a factory-built or gas fireplace, it follows the mantel chart in that fireplace's manual.
Before you pick a slab, bring us three numbers: how deep the mantel will be, the size of the fireplace opening, and the model of the fireplace if it is factory-built. We will pull the manual and tell you the lowest the mantel can sit. A deep, rough-cut beam usually has to go higher than people expect.
What about a wood stove?
A freestanding stove has its own floor protection and clearances, set by its listing and manual. Our post on what we check before a wood stove goes in covers the hearth pad and the distance to the wall and mantel.
Questions to ask before the hearth or mantel goes in
- Is the fireplace masonry or factory-built? It decides whether the code or the manual sets the numbers.
- If factory-built, what is the model? It is printed on the unit's rating plate, and it gets you the right manual.
- How big is the opening? On masonry, 6 square feet is the line between the two hearth sizes.
- How deep is the mantel, and how high will it sit? Check it against the projection rule or the manual's chart.
- Which code edition does the building department enforce? Ask when you apply for the permit, and ask whether the hearth or mantel work needs an inspection.
Shopping for the fireplace itself? Start with our fireplaces and inserts or the White Mountain Hearth line. Builders working through a spec can see how we work on new construction on the contractors page.
Sources
- Georgia Residential Code 2024 (2024 International Residential Code with Georgia amendments), chapter 10, as published by UpCodes, sections R1001.9, R1001.9.1 and R1001.9.2 for hearth and hearth extension materials, support and thickness and the raised-firebox exception, R1001.10 for hearth extension dimensions, R1001.11 for framing clearance, trim and sheathing edges and combustible mantels and trim, and R1004.1 and R1004.2 for factory-built fireplaces tested to UL 127 and installed to their listing
- Georgia Residential Code 2024, chapter 24, section G2434.1, for vented gas fireplaces listed to ANSI Z21.50/CSA 2.22 and installed to the manufacturer's instructions
- Empire Comfort Systems, DVCX42FP installation instructions and owner's manual, 41410-1-1024, listed as the Tahoe Luxury Traditional Fireplace on Empire's Tahoe manuals page, pages 9 and 10 for clearances to combustibles, the mantel chart, side wall and ceiling clearance, the television warning and the warning against attaching anything to the mantel, page 18 for mounting surfaces, page 29 for finishing, and page 5 for ANSI Z21.50 certification
The mantel numbers here are Empire's for the DVCX42FP. Other fireplaces have their own, in their own manuals. Nothing here replaces that manual or your local building department.
Planning a hearth or mantel?
Send us the opening size and the model.
We will look up the clearances for your fireplace and tell you how low the mantel can go. We call back within one business day.